Перевод: с русского на все языки

со всех языков на русский

НКУ внутренней установки

  • 1 НКУ внутренней установки

    1. Innen(raum)-Schaltanlagen und/oder -Schaltgeräte

     

    НКУ внутренней установки
    НКУ, предназначенное для эксплуатации внутри помещений
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    НКУ для внутренней установки

    НКУ, предназначенное для применения в местах, где выполняются условия нормальной эксплуатации внутри помещений согласно 7.1.
    [ ГОСТ Р МЭК 61439.1-2013]

    EN

    indoor switchgear and controlgear
    switchgear and controlgear designed solely for installation within a building or other housing, where the switchgear and controlgear is protected against wind, rain, snow, abnormal dirt deposits, abnormal condensation, ice and hoar frost
    [IEV number 441-11-04]

    assembly for indoor installation
    assembly which is designed for use in locations where the normal service conditions for indoor use as specified in 7.1 are fulfilled
    [IEC 61439-1, ed. 2.0 (2011-08)]

    FR

    appareillage pour l'intérieur
    appareillage qui n'est conçu que pour être installé à l'intérieur d'un bâtiment ou d'un autre abri, dans lequel l'appareillage est protégé contre le vent, la pluie, la neige, les pollutions anormales, la condensation anormale, la glace et le givre
    [IEV number 441-11-04]

    ensemble pour installation à l'intérieur
    ensemble destiné à être utilisé dans des locaux où les conditions normales d'emploi pour l'intérieur, spécifiées en 7.1, sont satisfaites
    [IEC 61439-1, ed. 2.0 (2011-08)]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    EN

    DE

    • Innen(raum)-Schaltanlagen und/oder -Schaltgeräte

    FR

    Русско-немецкий словарь нормативно-технической терминологии > НКУ внутренней установки

  • 2 НКУ внутренней установки

    1. indoor switchgear and controlgear
    2. assembly for indoor installation

     

    НКУ внутренней установки
    НКУ, предназначенное для эксплуатации внутри помещений
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    НКУ для внутренней установки

    НКУ, предназначенное для применения в местах, где выполняются условия нормальной эксплуатации внутри помещений согласно 7.1.
    [ ГОСТ Р МЭК 61439.1-2013]

    EN

    indoor switchgear and controlgear
    switchgear and controlgear designed solely for installation within a building or other housing, where the switchgear and controlgear is protected against wind, rain, snow, abnormal dirt deposits, abnormal condensation, ice and hoar frost
    [IEV number 441-11-04]

    assembly for indoor installation
    assembly which is designed for use in locations where the normal service conditions for indoor use as specified in 7.1 are fulfilled
    [IEC 61439-1, ed. 2.0 (2011-08)]

    FR

    appareillage pour l'intérieur
    appareillage qui n'est conçu que pour être installé à l'intérieur d'un bâtiment ou d'un autre abri, dans lequel l'appareillage est protégé contre le vent, la pluie, la neige, les pollutions anormales, la condensation anormale, la glace et le givre
    [IEV number 441-11-04]

    ensemble pour installation à l'intérieur
    ensemble destiné à être utilisé dans des locaux où les conditions normales d'emploi pour l'intérieur, spécifiées en 7.1, sont satisfaites
    [IEC 61439-1, ed. 2.0 (2011-08)]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    EN

    DE

    • Innen(raum)-Schaltanlagen und/oder -Schaltgeräte

    FR

    Русско-английский словарь нормативно-технической терминологии > НКУ внутренней установки

  • 3 НКУ внутренней установки

    1. ensemble pour installation à l'intérieur
    2. appareillage pour l'intérieur

     

    НКУ внутренней установки
    НКУ, предназначенное для эксплуатации внутри помещений
    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    НКУ для внутренней установки

    НКУ, предназначенное для применения в местах, где выполняются условия нормальной эксплуатации внутри помещений согласно 7.1.
    [ ГОСТ Р МЭК 61439.1-2013]

    EN

    indoor switchgear and controlgear
    switchgear and controlgear designed solely for installation within a building or other housing, where the switchgear and controlgear is protected against wind, rain, snow, abnormal dirt deposits, abnormal condensation, ice and hoar frost
    [IEV number 441-11-04]

    assembly for indoor installation
    assembly which is designed for use in locations where the normal service conditions for indoor use as specified in 7.1 are fulfilled
    [IEC 61439-1, ed. 2.0 (2011-08)]

    FR

    appareillage pour l'intérieur
    appareillage qui n'est conçu que pour être installé à l'intérieur d'un bâtiment ou d'un autre abri, dans lequel l'appareillage est protégé contre le vent, la pluie, la neige, les pollutions anormales, la condensation anormale, la glace et le givre
    [IEV number 441-11-04]

    ensemble pour installation à l'intérieur
    ensemble destiné à être utilisé dans des locaux où les conditions normales d'emploi pour l'intérieur, spécifiées en 7.1, sont satisfaites
    [IEC 61439-1, ed. 2.0 (2011-08)]

    Тематики

    • НКУ (шкафы, пульты,...)

    Классификация

    >>>

    EN

    DE

    • Innen(raum)-Schaltanlagen und/oder -Schaltgeräte

    FR

    Русско-французский словарь нормативно-технической терминологии > НКУ внутренней установки

  • 4 НКУ для внутренней установки

    Русско-английский словарь нормативно-технической терминологии > НКУ для внутренней установки

  • 5 НКУ распределения и управления для строительных площадок (НКУ СП)

    1. low-voltage switchgear and controlgear assembly for construction sites
    2. assemblies for construction sites
    3. ACS

     

    НКУ распределения и управления для строительных площадок (НКУ СП)
    Комбинация одного или нескольких трансформаторных устройств или коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты и регулирования со всеми внутренними электрическими и механическими соединениями и конструктивными элементами, разработанная и изготовленная для применения на любых строительных площадках — для наружной и внутренней установки.
    [ ГОСТ Р 51321. 4-2000 ( МЭК 60439-4-90)]

    EN

    low-voltage switchgear and controlgear assembly for construction sites (ACS)
    combination of one or several transforming or switching devices with associated control, measuring, signalling, protective and regulating equipment complete with all their internal electrical and mechanical connections and structural parts, designed and built for use on all construction sites, indoors and outdoors
    [IEC 60439-4, ed. 2.0 (2004-06)]

    FR

    ensemble d'appareillage à basse tension utilisé sur les chantiers (EC)
    combinaison d'un ou de plusieurs appareils de transformation ou de connexion avec équipements associés de commande, de mesure, de signalisation, de protection et de régulation complètement assemblés avec toutes leurs liaisons internes électriques et mécaniques et leurs éléments de construction (voir 2.4), conçue et construite pour être utilisée sur tous les chantiers, à l'intérieur et à l'extérieur.
    [IEC 60439-4, ed. 2.0 (2004-06)]

    0480
    Рис. ABB

    0481
    Рис. ABB

    0482
    Рис. ABB

    НКУ СП, устанавливаемое на ножках

    НКУ СП, закрепляемое на вертикальной поверхности

    НКУ СП розеточное

    Параллельные тексты EN-RU

     

    Assemblies for construction sites have different dimensions, ranging from the simple socket-outlet units to proper distribution boards in metal enclosure or insulating material.
    These assemblies are usually mobile.
    The Standard IEC 60439-4 establishes the particular requirements for this type of assemblies, making specific reference to mechanical strength and resistance to corrosion.

    [ABB]

    НКУ для строительных площадок имеют разные размеры и функции - от простых розеточных до распределительных панелей в металлической или пластмассовой оболочке.
    Данные НКУ обычно являются переносными.
    Стандарт МЭК 60439-4 устанавливает дополнительные требования для НКУ данного типа, особенно по механической прочности и коррозионной стойкости.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    FR

    Русско-английский словарь нормативно-технической терминологии > НКУ распределения и управления для строительных площадок (НКУ СП)

  • 6 НКУ распределения и управления для строительных площадок (НКУ СП)

    1. ensemble d'appareillage à basse tension utilisé sur les chantiers
    2. EC

     

    НКУ распределения и управления для строительных площадок (НКУ СП)
    Комбинация одного или нескольких трансформаторных устройств или коммутационных аппаратов с устройствами управления, измерения, сигнализации, защиты и регулирования со всеми внутренними электрическими и механическими соединениями и конструктивными элементами, разработанная и изготовленная для применения на любых строительных площадках — для наружной и внутренней установки.
    [ ГОСТ Р 51321. 4-2000 ( МЭК 60439-4-90)]

    EN

    low-voltage switchgear and controlgear assembly for construction sites (ACS)
    combination of one or several transforming or switching devices with associated control, measuring, signalling, protective and regulating equipment complete with all their internal electrical and mechanical connections and structural parts, designed and built for use on all construction sites, indoors and outdoors
    [IEC 60439-4, ed. 2.0 (2004-06)]

    FR

    ensemble d'appareillage à basse tension utilisé sur les chantiers (EC)
    combinaison d'un ou de plusieurs appareils de transformation ou de connexion avec équipements associés de commande, de mesure, de signalisation, de protection et de régulation complètement assemblés avec toutes leurs liaisons internes électriques et mécaniques et leurs éléments de construction (voir 2.4), conçue et construite pour être utilisée sur tous les chantiers, à l'intérieur et à l'extérieur.
    [IEC 60439-4, ed. 2.0 (2004-06)]

    0480
    Рис. ABB

    0481
    Рис. ABB

    0482
    Рис. ABB

    НКУ СП, устанавливаемое на ножках

    НКУ СП, закрепляемое на вертикальной поверхности

    НКУ СП розеточное

    Параллельные тексты EN-RU

     

    Assemblies for construction sites have different dimensions, ranging from the simple socket-outlet units to proper distribution boards in metal enclosure or insulating material.
    These assemblies are usually mobile.
    The Standard IEC 60439-4 establishes the particular requirements for this type of assemblies, making specific reference to mechanical strength and resistance to corrosion.

    [ABB]

    НКУ для строительных площадок имеют разные размеры и функции - от простых розеточных до распределительных панелей в металлической или пластмассовой оболочке.
    Данные НКУ обычно являются переносными.
    Стандарт МЭК 60439-4 устанавливает дополнительные требования для НКУ данного типа, особенно по механической прочности и коррозионной стойкости.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    FR

    Русско-французский словарь нормативно-технической терминологии > НКУ распределения и управления для строительных площадок (НКУ СП)

  • 7 НКУ с устройствами ограничения воздействия внутренней дуги

    1. assembly equipped with devices limiting internal arc effects

     

    НКУ с устройствами ограничения воздействия внутренней дуги
    -
    [Интент]

    Параллельные тексты EN-RU

    Assemblies equipped with devices limiting internal arc effects (active protection)

    A design philosophy which is completely different from that just considered consists in guaranteeing the resistance to internal arcing by installing devices limiting the arc.

    The approaches in that direction can be of two different types:
    • limiting the destructive effects of the arc, once it has occured, by means of arc detectors
    • limiting the destructive effects of the arc, once it has occured, by means of overpressure detectors.

    The first possibility consists in installing in the assembly arc detectors which sense the light flux associated with the electric arc phenomenon.

    Once the arc has been detected, these devices send an opening signal to the incoming circuit-breaker, thus guaranteeing tripping times of the order of 1-2 ms, therefore shorter than those proper of the circuit-breaker.

    The operating logic of an arc detector is the following: the occurrence of an arc inside the switchboard is detected by the arc detector because an intense light radiation is associated with this phenomenon.

    The arcing control system detects the event and sends a tripping signal to the circuit-breaker.

    All the above with trip times of a few milliseconds and supplanting the tripping of the CB overcurrent relay which, for example, could be delayed due to current selectivity questions.

    Figure 1 shows the possible positions where this device can be installed inside a switchboard.

    The ideal solution is that which provides the installation of at least one detector for each column, with the consequent reduction to a minimum of the length of the optical fibers carrying the signal.

    In order to prevent from an unwanted tripping caused by light sources indepent of the arc (lamps, solar radiation etc.), an additional current sensor is often positioned at the incoming of the main circuit-breaker.

    Only in the event of an arc, both the incoming sensor which detects an “anomalous” current due to the arc fault as well as the sensor detecting the light radiation as sociated with the arc enable the system to intervene and allow the consequent opening of the circuit-breaker.

    The second possibility consists in installing overpressure sensors inside the switchboard.

    As previously described, the overpressure wave is one of the other effects occurring inside an assembly in case of arcing.

    As a consequence it is possible to install some pressure sensors which are able to signal the pressure peak associated with the arc ignition with a delay of about 10-15 ms.

    The signal operates on the supply circuit-breaker without waiting for the trip times of the selectivity protections to elapse, which are necessarily longer.

    Such a system does not need any electronic processing device, since it acts directly on the tripping coil of the supply circuit-breaker.

    Obviously it is essential that the device is set at fixed trip thresholds.

    When an established internal overpressure is reached, the arc detector intervenes.

    However, it is not easy to define in advance the value of overpressure generated by an arc fault inside a switchboard.

    [ABB]

    НКУ с устройствами ограничения воздействия внутренней дуги (активная защита)

    Для решения этой задачи используются совершенно другие, отличающиеся от ранее рассмотренных, принципы, заключающиеся в том, что противодействие внутренней дуге обеспечивается применением устройств, ограничивающих саму дугу.

    Существует два типа решения проблемы в этом направлении:
    • ограничение разрушающего воздействия дуги после того, как ее обнаружат специальные устройства
    • ограничение разрушающего воздействия дуги после того, как специальные устройства обнаружат возникновение избыточного давления.

    В первом случае в НКУ устанавливают устройства обнаружения дуги, реагирующие на световой поток, сопровождающий явление электрической дуги.

    При обнаружении дуги данные устройства посылают сигнал управления на размыкание вводного автоматического выключателя. Гарантируемое время реакции составляет 1-2 мс, что меньше времени срабатывания автоматического выключателя.

    Логика работы устройства обнаружения дуги следующая: Дуга, возникшая внутри НКУ, обнаруживается датчиком, реагирующим на интенсивное световое излучение, которым сопровождается горение дуги.

    Обнаружив дугу, система управления посылает сигнал автоматическому выключателю.

    Время срабатывания датчика и системы управления составляет несколько миллисекунд, что меньше времени срабатывания автоматического выключателя, осуществляющего защиту от сверхтока, который обычно для обеспечения требуемой селективности срабатывает с задержкой.

    На рис. 1 показаны места возможной установки устройства защиты внутри НКУ.

    Идеальным решением является установка, по крайней мере, одного устройства защиты в каждый шкаф многошкафного НКУ.

    Это позволит до минимума сократить длину оптоволоконных кабелей передачи сигнала.

    Для предотвращения ложного срабатывания от других источников света (т. е. не от дуги), например, таких как лампы, солнечное излучение и т. п., дополнительно в главной цепи вводного автоматического выключателя устанавливают датчик тока.

    Только при наличии двух событий, а именно: срабатывания датчика света и обнаружения аномального увеличения тока, система управления считает, что возникла электрическая дуга и подает команду на отключение вводного автоматического выключателя.

    Второе решение заключается в установке внутри НКУ датчика избыточного давления.

    Как было описано ранее, одним из характерных проявлений электрической дуги, возникшей внутри НКУ, является ударная волна.

    Это означает, что можно установить несколько датчиков давления, задачей которых является обнаружение импульса давления (с задержкой 10…15 мс), обусловленного зажиганием дуги.

    Сигнал от датчиков давления поступает на вводной автоматический выключатель, который срабатывает без задержки на обеспечение селективности.

    Такая система не нуждается в электронном устройстве обработки информации, поскольку воздействует непосредственно на независимый расцепитель автоматического выключателя.

    Вполне понятно, что такое устройство имеет фиксированный порог срабатывания.

    Датчик-реле дуги сработает, как только будет достигнуто заданное значение избыточного давления.

    Следует иметь в виду, что не так легко заранее определить значение избыточного давления, которое будет создано при зажигании дуги внутри НКУ.

    [Перевод Интент]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    Русско-английский словарь нормативно-технической терминологии > НКУ с устройствами ограничения воздействия внутренней дуги

  • 8 проверка стойкости к коррозии и влажности

    1. verification of resistance to rusting and to humidity

     

    проверка стойкости к коррозии и влажности
    Входит в переченьт проверок и испытаний, проводнимых на НКУ при типовых испытаниях
    [ ГОСТ Р 51321. 3-99 ( МЭК 60439-3-90)]

    8.2.10 Проверка стойкости к коррозии и влажности
    Испытание распространяется на НКУ для внутренней установки без встроенных комплектующих элементов, на отдельные части или детали больших частей при условии, что они имеют такую же защиту от коррозии, что и вся конструкция. Альтернативно оно может выполняться на подготовленном образце с такой же защитой от коррозии.
    НКУ наружной установки не охватываются настоящим стандартом.
    Всю смазку удаляют с деталей или испытуемых образцов стальных оболочек распределительной панели путем погружения на 10 мин в холодный химический обезжириватель, как, например, хлористый метил или очищенный бензин. Затем детали погружают на 10 мин в водный 10%-ный раствор хлорида аммония при температуре (20±5) °С.
    После стекания капель, но без просушивания, детали помещают на 10 мин в камеру влажности при температуре (20±5) °С.
    После того как детали просушатся в течение 10 мин в термокамере при температуре (100±5) °С и выдержатся в течение 24 ч при комнатной температуре, их поверхности не должны иметь следов коррозии.
    Следы коррозии на острых краях и желтоватый налет, исчезающий после протирки, не принимают во внимание.
    Для небольших спиральных пружин и аналогичных им частей и недоступных деталей, подверженных истиранию, слой смазки может представлять собой достаточную защиту от коррозии. Подобные детали подвергают испытанию только в случае сомнения относительно эффективности смазочной пленки, и испытание проводят в этом случае без предварительного удаления смазки.

    [ ГОСТ Р 51321. 3-99 ( МЭК 60439-3-90)]

    Тематики

    • НКУ (шкафы, пульты,...)

    EN

    Русско-английский словарь нормативно-технической терминологии > проверка стойкости к коррозии и влажности

  • 9 условия эксплуатации (электрооборудования)

    1. working condition
    2. use environment
    3. usage conditions
    4. set of operating conditions
    5. service environment
    6. service conditions
    7. running conditions
    8. operational environment
    9. operational conditions
    10. operation conditions
    11. operating conditions
    12. operating condition
    13. in-use conditions
    14. field conditions
    15. external environment
    16. environmental service conditions
    17. environment
    18. EE
    19. conditions of usage
    20. application environment
    21. application conditions

     

    условия эксплуатации
    Совокупность значений внешних воздействующих факторов, которые во время эксплуатации электротехнического изделия (электротехнического устройства, электрооборудования) могут на него влиять.
    [ ГОСТ 18311-80]

    КЛАССИФИКАЦИЯ (по ГОСТ Р МЭК 61439-1-2012)

    • Условия эксплуатации:
      • Нормальные условия эксплуатации:
        • температура окружающей среды:
          • при внутренней установке (при установке внутри помещения);
          • при наружной установке (при установке вне помещения);
        • атмосферные условия:
          • относительная влажность воздуха;
          • степень загрязнения;
        • высота над уровнем моря;
      • Особые условия эксплуатации:
        • значения температуры окружающей среды, относительной алжности воздуха, высоты над уровнем моря, отличающиеся от нормальных условий эксплуатации;
        • места установки, в которых температура окружающей среды и/или атмосферное давление могут изменяться так быстро, что внутри НКУ будет происходить образование конденсата в значительном количестве;
        • сильное загрязнение воздуха пылью; наличие в воздухе дыма, коррозионных или радиоактивных частиц, испарений или соли;
        • воздействие сильных электрических или магнитных полей;
        • воздействие экстремальных климатических условий;
        • образование плесени или воздействие микроорганизмов;
        • установка в пожаро- или взрывоопасных местах;
        • воздействие сильной вибрации или ударов;
        • способ установки, приводящий к снижению допустимых токовых нагрузок или отключающей способности устройств, например, встаривание в машину или нишу в стене;
        • воздействие наведенных или излучаемых помех, кроме электромагнитных и электромагнитных помех, кроме указанных в п. 9.4;
        • повышеннные перенапряжения.

    НКУ должно эксплуатироваться в нормальных условиях эксплуатации.

    НКУ, соответствующие требованиям настоящего стандарта, должны эксплуатироваться в указанных ниже условиях....

    6.1.1 Температура окружающего воздуха

    6.1.1.1 Температура окружающего воздуха при внутренней установке...
    6.1.1.2 Температура окружающего воздуха при наружной установке...

    6.1.2 Атмосферные условия

    6.1.2.1 Атмосферные условия при установке внутри помещений...
    6.1.2.2 Атмосферные условия при наружной установке...

    6.1.2.3 Степень загрязнения...

    6.1.3 Высота над уровнем моря мест установки...

    [ ГОСТ Р 51321. 1-2000 ( МЭК 60439-1-92)]

    Параллельные тексты EN-RU

    The operation characteristic of Molded Case Circuit Breaker including short-circuit, overload, endurance and insulation is often influenced largely by external environment and thus should be applied appropriately with conditions of the place where it is used taken into consideration.
    [LS Industrial Systems]

    Рабочие характеристики автоматического выключателя в литом корпусе, такие, как срабатывание защиты от короткого замыкания и перегрузки, коммутационная износостойкость и изоляционное расстояние, часто в значительной степени зависят от окружающей среды. Поэтому при установке выключателя необходимо учитывать условия, существующие в месте предстоящей эксплуатации выключателя.
    [Перевод Интент]


     

    Тематики

    Действия

    Синонимы

    Сопутствующие термины

    EN

    Русско-английский словарь нормативно-технической терминологии > условия эксплуатации (электрооборудования)

См. также в других словарях:

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»